Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-CHB0AC-P-A-DK00000 Advanced Energy CX10S-CHB0AC-P-A-DK00000 -
RFQ
ECAD 3500 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHB0AC-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 24V 5V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 15 A 21 A 8.3 A
CX10S-C00GGA-P-A-DK00000 Advanced Energy CX10S-C00GGA-P-A-DK00000 -
RFQ
ECAD 7631 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00GGA-P-A-DK00000 EAR99 8504.40.9540 1 545W 6 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 3 A 3 A 21 A
MP4-1L-1L-10 Artesyn Embedded Power MP4-1L-1L-10 -
RFQ
ECAD 9786 0.00000000 Artesyn Embedded Power MP4 (600W) Bulk Obsolete -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote Sense, Standby Output, Universal Input CB, CE, CSA, UL, VDE 85 ~ 264 VAC, 120 ~ 300 VDC download Not Applicable EAR99 8504.40.7018 1 600W 2 85% 12V 24V - - - - - 17 A 17 A
CX10S-0DDCBD-P-A-DK00000 Advanced Energy CX10S-0DDCBD-P-A-DK00000 -
RFQ
ECAD 4711 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DDCBD-P-A-DK00000 EAR99 8504.40.9540 1 980W 5 93% 48V 48V 24V 12V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 8.3 A 15 A 4.17 A
CX10S-B0AGDC-P-A-DK00000 Advanced Energy CX10S-B0AGDC-P-A-DK00000 -
RFQ
ECAD 7080 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-B0AGDC-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 12V 5V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 3 A 3 A 4.17 A 8.3 A
VI-RA014-EVXX Vicor Corporation VI-RA014-EVXX -
RFQ
ECAD 9755 0.00000000 Vicor Corporation * Bulk Obsolete VI-RA014 - 1 (Unlimited) REACH Affected EAR99 8504.40.9530 1
CX10S-GCCCHA-P-A-DK00000 Advanced Energy CX10S-GCCCHA-P-A-DK00000 -
RFQ
ECAD 8986 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCCCHA-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 24V 24V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 8.3 A 8.3 A 6 A
CX10S-H0HBGC-P-A-DK00000 Advanced Energy CX10S-H0HBGC-P-A-DK00000 -
RFQ
ECAD 1975 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0HBGC-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 5V 24V 5V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 15 A 3 A
CX10S-0BHGDB-P-A-DK00000 Advanced Energy CX10S-0BHGDB-P-A-DK00000 -
RFQ
ECAD 5090 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BHGDB-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 12V 5V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 3 A 3 A 4.17 A
CX10S-DHDHBG-P-A-DK00000 Advanced Energy CX10S-DHDHBG-P-A-DK00000 -
RFQ
ECAD 2952 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DHDHBG-P-A-DK00000 EAR99 8504.40.9540 1 900W 9 93% 48V 5V 24V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 6 A 3 A 4.17 A 6 A 3 A
CX10S-BAGDC0-P-A-DK00000 Advanced Energy CX10S-BAGDC0-P-A-DK00000 -
RFQ
ECAD 9864 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BAGDC0-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 12V 5V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 3 A 3 A 4.17 A 8.3 A
CX10S-DAAGAD-P-A-DK00000 Advanced Energy CX10S-DAAGAD-P-A-DK00000 -
RFQ
ECAD 7270 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DAAGAD-P-A-DK00000 EAR99 8504.40.9540 1 835W 7 93% 48V 5V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 21 A 3 A 3 A 21 A
RPS-500-12-C MEAN WELL USA Inc. RPS-500-12-C 118.9300
RFQ
ECAD 66 0.00000000 MEAN WELL USA Inc. RPS-500 (500W) Box Active -30°C ~ 70°C (With Derating) Medical 5.12" L x 3.39" W x 1.69" H (130.0mm x 86.0mm x 43.0mm) Chassis Mount Enclosed Adjustable Output, PFC, Remote Sense, Universal Input RPS-500 CB, CE, cURus, EAC, TUV 80 ~ 264 VAC, 113 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected 1866-5599 EAR99 8504.40.9530 30 310W (500W Forced Air) 1 91% 12V - - - - - - 4 kV 25.8 A
CX10S-CCBAHH-P-A-DK00000 Advanced Energy CX10S-CCBAHH-P-A-DK00000 -
RFQ
ECAD 3551 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCBAHH-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 24V 24V 12V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 15 A 21 A 6 A 3 A
IMP4-2E0-1L0-4LL-00-A Artesyn Embedded Power IMP4-2E0-1L0-4LL-00-A -
RFQ
ECAD 5536 0.00000000 Artesyn Embedded Power iMP® (1158W) Bulk Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 10.00" L x 5.00" W x 2.50" H (254.0mm x 127.0mm x 63.5mm) Chassis Mount Enclosed Adjustable Output, I²C Interface, PFC, PMBus™, Remote Sense, Universal Input IMP4-2E0 CB, CE, CSA, UL 85 ~ 264 VAC, 120 ~ 300 VDC download RoHS Compliant Not Applicable EAR99 8504.40.9540 1 672W 4 85% 5V 12V 12V 12V - - No 2 kV 60 A 17 A 10 A 4 A
CX10S-DGB0HA-P-A-DK00000 Advanced Energy CX10S-DGB0HA-P-A-DK00000 -
RFQ
ECAD 3108 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGB0HA-P-A-DK00000 EAR99 8504.40.9540 1 705W 7 93% 48V 24V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 6 A 3 A
MAP55-4004G Bel Power Solutions MAP55-4004G 262.6000
RFQ
ECAD 87 0.00000000 Bel Power Solutions MAP55 (55W) Bulk Active 0°C ~ 70°C (With Derating) ITE (Commercial) 6.00" L x 3.27" W x 1.60" H (152.4mm x 83.1mm x 40.6mm) Chassis Mount Open Frame Adjustable Output, Universal Input MAP55 CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.7007 10 55W 4 73% 5V 24V -15V 15V - Yes 2.6 kV 6 A 1.5 A 500 mA 500 mA
NMP1K2-CCHHKH-01 MEAN WELL USA Inc. NMP1K2-CCHHKH-01 821.0300
RFQ
ECAD 7714 0.00000000 MEAN WELL USA Inc. NMP (1200W) Box Active -30°C ~ 70°C (With Derating) ITE (Commercial), Medical 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) Chassis Mount Enclosed Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input NMP1K2 CB, CE, cURus, EAC, TUV 90 ~ 264 VAC, 120 ~ 370 VDC download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9540 1 1200W 5 88.5% 5V 24V 24V 48V 24V - - 4 kV 60601-1; 62368-1 72 A 10 A 10 A 5 A 10 A
CX10S-CBDBGD-P-A-DK00000 Advanced Energy CX10S-CBDBGD-P-A-DK00000 -
RFQ
ECAD 3959 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBDBGD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 12V 48V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 4.17 A 15 A 3 A 3 A
CX10S-GAHBBC-P-A-DK00000 Advanced Energy CX10S-GAHBBC-P-A-DK00000 -
RFQ
ECAD 7087 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAHBBC-P-A-DK00000 EAR99 8504.40.9540 1 885W 8 93% 24V 24V 5V 5V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 15 A
HWS150A-3/RA TDK-Lambda Americas Inc HWS150A-3/RA -
RFQ
ECAD 8996 0.00000000 TDK-Lambda Americas Inc HWS-A (150W) Bulk Active -10°C ~ 70°C (With Derating) Industrial, ITE (Commercial) 6.30" L x 1.65" W x 3.23" H (160.0mm x 41.9mm x 82.0mm) Chassis Mount Enclosed Adjustable Output, Remote On/Off, Remote Sense, Universal Input HWS150 CE 85 ~ 265 VAC, 120 ~ 370 VDC download RoHS Compliant Not Applicable REACH Unaffected EAR99 8504.40.9520 1 99W 1 84% 3.3V - - - - - - 3 kV 30 A
CX10S-DDDGBC-P-A-DK00000 Advanced Energy CX10S-DDDGBC-P-A-DK00000 -
RFQ
ECAD 8367 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DDDGBC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 48V 48V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 4.17 A 3 A 3 A 15 A
DHF030-7 Tri-Mag, LLC DHF030-7 32.9180
RFQ
ECAD 5639 0.00000000 Tri-Mag, LLC Tri-Mag, DHF030 (30W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 2.76" L x 1.57" W x 0.90" H (70.0mm x 40.0mm x 23.0mm) Chassis Mount Open Frame Universal Input DHF030 CB, CE 90 ~ 264 VAC download ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.6018 1 30W (36W Forced Air) 1 87% 12V - - - - - 2.5 A
CX10S-CA0DGC-P-A-DK00000 Advanced Energy CX10S-CA0DGC-P-A-DK00000 -
RFQ
ECAD 9280 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CA0DGC-P-A-DK00000 EAR99 8504.40.9540 1 825W 6 93% 24V 5V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 4.17 A 3 A 3 A 8.3 A
CX10S-C00GBB-P-A-DK00000 Advanced Energy CX10S-C00GBB-P-A-DK00000 -
RFQ
ECAD 4894 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C00GBB-P-A-DK00000 EAR99 8504.40.9540 1 680W 5 93% 24V 24V 24V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 15 A 15 A
CX10S-HCGG0D-P-A-DK00000 Advanced Energy CX10S-HCGG0D-P-A-DK00000 -
RFQ
ECAD 2418 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HCGG0D-P-A-DK00000 EAR99 8504.40.9540 1 540W 8 93% 5V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 8.3 A 3 A 3 A 3 A
CX10S-ABGCDH-P-A-DK00000 Advanced Energy CX10S-ABGCDH-P-A-DK00000 -
RFQ
ECAD 4611 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABGCDH-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 5V 12V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 3 A 3 A 8.3 A 4.17 A
CX10S-HDC0BB-P-A-DK00000 Advanced Energy CX10S-HDC0BB-P-A-DK00000 -
RFQ
ECAD 9521 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDC0BB-P-A-DK00000 EAR99 8504.40.9540 1 860W 6 93% 5V 24V 48V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 8.3 A 15 A 15 A
CX10S-HH0DCG-P-A-DK00000 Advanced Energy CX10S-HH0DCG-P-A-DK00000 -
RFQ
ECAD 4134 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HH0DCG-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 5V 24V 5V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 4.17 A 8.3 A
CX10S-H0GBBG-P-A-DK00000 Advanced Energy CX10S-H0GBBG-P-A-DK00000 -
RFQ
ECAD 3184 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0GBBG-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 5V 24V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 15 A 15 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse